EPIAIDEA
Epidemiology · AI · Data · Evidence · Action
Methods Note

A disproportionality signal
is not evidence of causation

The most common error I am asked to review is not a miscalculated ROR. It is a correctly calculated ROR carrying a conclusion it cannot support.

5 November 2026· Pharmacovigilance· 9 min read

Spontaneous reporting databases — FAERS, VigiBase, EudraVigilance — are the backbone of post-marketing safety surveillance, and disproportionality analysis is how we read them at scale. The arithmetic is simple: build a 2×2 table of the drug of interest against the event of interest, with the rest of the database as the comparator, and ask whether the pair appears more often than expected.

That gives you a reporting odds ratio, a proportional reporting ratio, or their Bayesian relatives. All of them answer one question, and it is narrower than it looks:

Is this drug–event pair reported more often, relative to everything else in this database, than the rest of the database would predict?

Note what is absent. Not does the drug cause the event. Not how often the event occurs. Not how the risk compares to an alternative treatment. The measure is about reporting, and the comparator is the database itself.

The denominator you do not have

A rate needs a numerator and a denominator. Spontaneous reporting gives you a numerator of uncertain completeness and no denominator at all. You do not know how many people took the drug, for how long, at what dose, or with what comorbidity. Without that, no incidence can be computed — only a comparison of reporting proportions.

This is why the ratio is relative to the database. If reporting of everything else shifts, a drug's ROR moves without anything changing about the drug. That is not a subtle statistical artefact; it is the central property of the measure.

Six mechanisms that produce a signal with no causal content

1. Notoriety bias

A drug in the news gets reported more. Litigation, a regulatory communication, a viral patient account — each raises reporting for that drug and that event specifically. The signal then rises, and the rise is often read as confirmation of the very story that caused it. This is the most important single mechanism to rule out, and the easiest to miss, because the timing looks like discovery.

2. The Weber effect and product lifecycle

Reporting for a new drug typically peaks in the first years after launch and declines thereafter, independent of actual risk. Comparing a recently approved agent to an established one therefore compares two different points on two different reporting curves.

3. Confounding by indication

The condition being treated produces the event. An antidiabetic agent will show an association with renal outcomes because diabetes damages kidneys. The database records the drug and the event; it has no field for why the drug was prescribed.

4. Masking, or competition bias

Because the comparator is the rest of the database, one heavily reported drug–event pair suppresses disproportionality for every other drug with that same event. A genuine signal can be hidden by a louder one. This cuts in the direction people rarely check: a null result in a crowded event category is weak evidence of safety.

5. Stimulated and channelled reporting

Risk management programmes, registries, and plaintiff-side reporting campaigns all generate reports non-randomly. So do prescribing patterns: if the sickest patients are channelled to the newest drug, its report profile reflects their baseline risk.

6. Duplicates and attribution artefacts

The same case can enter a database several times through different routes. A single report may list many suspect drugs, and disproportionality methods generally do not know which one the reporter actually blamed.

So what is it good for?

A great deal — provided the claim matches the method. Disproportionality analysis is a screening and triage instrument. Its legitimate outputs are:

  • Hypothesis generation. Surfacing pairs worth a properly designed study, out of millions that are not.
  • Prioritisation. Deciding which of forty candidate signals gets the next analyst-month.
  • Early detection of the rare and acute. For events too uncommon for a trial to have caught and temporally close enough to exposure to be noticed, spontaneous reporting is often genuinely first.
  • Characterising a reporting environment. Who reports, how quickly, with what quality — a legitimate object of study in itself, and directly relevant to risk communication.

What it cannot do is quantify risk, support a causal claim on its own, or compare two drugs' safety profiles. For those you need a design with a denominator and a defensible comparator: an active-comparator new-user cohort, a self-controlled case series, a case–crossover study, or a target trial emulation in claims or electronic health records.

A sentence structure that keeps you honest

When I review these analyses, I rewrite the key claim into this form and see whether it still says anything the author wanted it to say:

"In [database], between [dates], reports of [event] among reports mentioning [drug] were [n]-fold more frequent than among all other reports, which is consistent with — but does not establish — [hypothesis], and is also consistent with [the most plausible reporting artefact]."

If the final clause cannot be filled in, the analysis is not finished. If filling it in makes the conclusion uninteresting, the signal was the artefact. That second outcome is a successful analysis, not a failed one — it is exactly what a screening instrument is supposed to do.

Why the distinction has consequences

This is not pedantry about wording. Disproportionality results are cited in regulatory submissions, in label-change discussions, in expert reports, and increasingly in litigation, where an opposing expert will know precisely what the measure does and does not support. An over-stated ROR is the easiest finding in pharmacoepidemiology to dismantle, and dismantling it tends to take the credible parts of the analysis down with it.

The same discipline applies with more force to automated and AI-assisted signal detection. A pipeline that screens every drug–event pair in a database will generate thousands of statistically disproportionate results, and the overwhelming majority will be reporting artefacts. Scale does not improve the evidentiary status of the measure — it multiplies the number of claims that need the final clause filled in.

↑